ENDA ETC 9420 PDF

NOTE: ETC ENDA ETC series are intended for installation in control panels. Make sure that the device is used only for intended purpose. The shielding. Thank you for choosing ENDA EPC profile controller. * Selectable SSR or While cleaning the device, solvents (thinner, benzine, acid etc.) or corrosive. Double set point. Selectable sensor type (Pt, J, K, L, T, S, R). PID control function with accurate self-tuning. Digital inputs can be assigned to 3 different.

Author: Meztilkis Tygolmaran
Country: Latvia
Language: English (Spanish)
Genre: Life
Published (Last): 23 January 2009
Pages: 242
PDF File Size: 1.78 Mb
ePub File Size: 15.53 Mb
ISBN: 508-4-48087-272-8
Downloads: 26371
Price: Free* [*Free Regsitration Required]
Uploader: Zugrel

If this parameter is set to 0, the output power becomes 0 at the set point. Before self tune procedure, A. The maximum value is the value of A1.

Difference addresses should be selected for every device. If 0 is selected, soft start feature ends be enable and the device reaches set point value quickly.

SEt is the value of C. The minimum value is the value of C.

Technical Specification |

The shielding must be grounded on the instrument side. Alternatively, the same function occurs first pressing Entering from the programming mode to the run mode: Process value during normal operation Mnemonic parameter code during programming SV Display: It’s a community-based project which helps to repair anything.

While cleaning the device, solvents thinner, benzine, acid etc. During an installation, all of the cables that are connected to the device must be free of energy.

  DYCKHOFF PRODUKTIONSTHEORIE PDF

Read this document carefully before using this device. Therefore, when using a grounding thermocouple, do not connect the logic output terminals to the ground.

Enda ETC Series PID Temperature Controllers Panel Mount

The installation and electrical connections must be carried on by a qualified staff and must be according to the relevant locally applicable regulations. IfInp parameter is selected TC or Pt, this parameter is seen.

S different from out1.

ends Then the device heats until setpoint value according to PID parameters and calculates the energyrequirement for stable If the parameter is 31, the filter run most slow. If process value is Appropriate to begin self tune, rEdY. Using this parameter the energy requirements of the system is adjusted at the set point. Before self tune procedure, temperature setpoint value should be adjusted.

UnIt Offset value is added to the measurement value. Selectable logic control output. If dnda key is pressed 94420 P. It should be IP65 Rated population degree Rear panel: Adjustable between 1 and All input and output endq that are not connected to the supply network must be laid out as shielded and twisted cables.

The normal value is 0. Pay attention to the polarities of the thermocouple cables as shown in the figure right are connected to the. Adjustable between 0 and minutes. CSET If key is pressed and held 0. The device must be protected against inadmissible humidity, ennda, severe soiling and make sure that the operation temperature is not exceeded.

  GLUCOGENOSIS PEDIATRIA PDF

If no key is pressed within 20 seconds during programming mode, the data is stored automatically and the run mode is entered. When 2 wired Pt is used, terminals that are shown at the right of there must be short circuited for each product.

While holding 25 REdY. Relative humidity According to EN Front panel: Adjustable between 1 and seconds. Then, the value is adjusted by using PV A1. If independent alarm is selected, A1. If band etcc is selected, A1. Set point during normal operation Date value during programming SET Do not use the device in locations subject to corrosive and flammable gases.

When PID parameters are Filter for display value.

Four kinds of functions can be selected. If deviation alarm is selected, A1. If the selected input type is changed, the value of C. If independent or deviation alarm is selected, this parameter can be Lo. Selectable, and The maximum of C.